[yith_ywraq_button_quote]

Kit of two filters A1B1E1K1 limited capacity for semi-mask M6200-JUPITER

0,00 EUR IVA esclusa

[yith_ywraq_button_quote]

Descriptive:

Kit of two filters A1B1E1K1 limited capacity for semi-mask M6200-JUPITER.

Materials:

Plastic shell and synthetic fibers.

Instructions for use:

Filter weak capacity (for a gas-tight <0.1% by volume) that protects against organic gases and vapors, at the boiling point above 65 ° C, against certain inorganic gases (chlorine, hydrogen sulfide, hydrocyanic acid) except for the ‘carbon monoxide, sulfur dioxide and against certain gases and acid vapors (sulfur dioxide, hydrochloric acid), and against the gas of ammonia and certain derivatives. Replace in the present case an increase of resistance to breathing or if any odor is perceived by the user. Check that the data on the type of filter match the intended use.

Limitations of use:

Do not use the filter outside the scope of use defined in the instructions and carefully read the operating instructions that accompany the product before use. The filters can be used without danger when: – the concentration of oxygen in the surrounding air is not less than 19.5% by volume -, the type and characteristics of the toxic substance are well known – the limits of use of the filters , according to the concentration of air pollution, are respected -, respiratory filters do not serve under any circumstances if used in small spaces non-ventilated (containers, wells,. ..) in case of danger caused by lack of oxygen (less than 19.5% volume) or a large concentration of harmful substances, the operator must use a device that ensures complete protection. Can not be used against radioactive materials, micro-organisms and biochemical material.

Instructions for storage:

The storage of the filters must be done in a clean, protected from heat and sunlight. The temperature should be between -5 ° C and + 35 ° C with a? Relative humidity 75% ceiling. If the filters are not stored in their
own packing d ‘origin or if they are not stored under the recommended conditions the expiration date printed on the filter may no longer be valid.

Instructions for cleaning / maintenance:

No cleaning advocated. Defective components should be replaced immediately. Use only spare parts and filters of origin. Properly stored in its original packaging, the filters do not require maintenance.

Performance:

Complies with the requirements of the European Directive 89/686, in particular in terms of ergonomics, safety, comfort, and the standard EN14387: 2004 (A1B1E1K1).

Scrivi per maggiori informazioni

Contatta un consulente

0,00 EUR IVA esclusa